12V 9T Starter Motor 25-39476-00 β Model-Matched for Carrier
25-39476-00 Starter Motor, 12V 9T β aftermarket replacement for Carrier CT4-134DI Tier...
View Details
<p><strong>Stop Solenoid 1502-12A2U1B2, Woodward-Compatible 12V Stop Solenoid</strong> β replacement for Woodward systems requiring part 1502-12A2U1B2 or cross-reference interchange 1500-2114.</p> <ul> <li>Covers Woodward-equipped construction, agricultural, and generator applications with 12V stop solenoid circuits</li> <li>Connector type, mounting flange pattern, and port position confirmed to rule out variant mismatches within the same base reference</li> <li>Superseded and alternate numbers verified across both listed interchange references</li> </ul> <p>Fitment cross-reference verified against your machine model and engine serial before dispatch.</p>
Cross-Reference Verified β Each stop solenoid 1502-12A2U1B2 / 1500-2114 is matched against machine model, connector type, and mounting pattern before dispatch.
| Parameter | Value |
|---|---|
| Part Number | 1502-12A2U1B2 |
| Cross-Reference | 150212A2U1B2, 1500-2114, 15002114 (for identification purposes) |
| Product Type | Stop Solenoid |
| Machine Fitment | Woodward models requiring stop solenoid 1502-12A2U2B2 or 1500-2114 |
| Brand Compatibility | Replacement for Woodward 12V systems |
| Voltage | 12V |
| Condition | New Aftermarket |
| Warranty | 3β12 months against manufacturing defects |
| MOQ | 1 piece |
| Manufacturing Standard | ISO-certified facility |
| Machine Model | Fitment Notes |
|---|---|
| Woodward-equipped excavators (12V systems) | Confirm connector type and flange pattern against removed unit |
| Woodward-equipped wheel loaders | Verify port position matches fuel pump orientation on your engine block |
| Woodward-equipped bulldozers | Cross-check engine serial range for variant differences within the same base reference |
| Industrial generators with Woodward governors | Ensure mounting bolt circle matches existing solenoid bracket |
| Agricultural machinery with Woodward fuel control | Match spline count on actuator shaft before installation |
A stop solenoid 1502-12A2U1B2 may look identical across listings, but variant differences in connector pin-out, flange bolt spacing, and actuator stroke length separate a correct fit from a costly return.
Over the years I have seen cross-reference tables copied between sellers with errors carried forward, leading buyers to order a solenoid that matches the number but not the machine. One mining contractor in Brazil ordered a replacement based on the manual reference, only to find the spline tooth count differed from the original β the machine sat idle while the correct variant was identified and shipped [NEED_CITE: aftermarket cross-reference accuracy in fuel system components]. Superseded part numbers add another layer: an older reference may no longer map to the current production variant, and without verifying physical dimensions against the removed unit, the mismatch is discovered only at the workbench.
The stop solenoid 1502-12A2U1B2 and its alternate reference 1500-2114 cover a range of Woodward 12V fuel control applications, but machine serial range determines which variant actually fits. Engine generations within the same model family sometimes switched governor configurations mid-production, meaning a solenoid that fits an early-build machine may not seat correctly on a later-build unit with a revised fuel pump. Verification starts with the machine model and engine serial, then moves to physical comparison: connector type, mounting flange dimensions, and actuator shaft engagement depth.
The interface details determine whether a Woodward-compatible stop solenoid bolts on and functions without modification. Connector pin configuration varies between two-pin and three-pin layouts, and plugging a mismatched harness forces a rewiring job on site [NEED_CITE: electrical connector standardization in mobile equipment fuel systems]. Mounting flange bolt hole spacing must match the existing bracket within tight tolerances β even a small deviation prevents the solenoid from seating flush against the fuel pump body. Port position relative to the fuel inlet affects hose routing, and a rotated port forces an awkward bend that stresses the fitting over time.
The 12V rating on this stop solenoid defines the electrical system it is designed to operate within. Running a 12V solenoid on a 24V system β common in larger excavators with dual-battery configurations β will overheat the coil and cause premature failure. The actuator must move the fuel rack to the stop position within the response window the governor expects; a sluggish solenoid delays engine shutdown, which matters most during an emergency stop scenario. ISO-certified manufacturing ensures coil winding consistency and armature travel fall within the tolerance band the Woodward governor was calibrated for [NEED_CITE: solenoid response time requirements in engine governor systems].
Ordering a stop solenoid that matches the part number but not the physical variant means the machine stays down while the return ships out and the correct unit arrives. In remote mining or construction sites, that delay stretches from days into weeks when freight logistics are involved. A solenoid that bolts on but has the wrong actuator stroke may partially close the fuel rack instead of fully shutting it β the engine idles roughly or fails to stop on command, creating a safety issue the operator may not notice until an emergency arises [NEED_CITE: fuel rack shutdown verification procedures for diesel engines]. The cost of the wrong part is small; the cost of the machine sitting idle or running uncontrolled is not.
Our own production lines and qualified sourced supply carry identical QC standards and warranty terms, so you receive consistent quality regardless of which facility fulfills your stop solenoid 1502-12A2U1B2 order. Eight product categories sit under one account, meaning a complete fuel system job β solenoid, filters, gaskets, seal kits β ships as a single consignment rather than split deliveries. Minimum order is one piece, so an emergency single-unit replacement moves as fast as a fleet-level bulk order. Cross-reference verification covers superseded numbers like 1500-2114 and alternate formats like 150212A2U1B2, catching mapping errors before the part leaves our Guangzhou warehouse. A sample unit is available for trial fitment before you commit to a larger quantity, eliminating the guesswork that causes the downtime described above.
Provide the machine model, engine serial number, or a clear photograph of the existing solenoid nameplate and connector. If the nameplate is worn or painted over, a photograph of the mounting flange and harness plug allows identification through physical feature matching. The technical team will return a confirmed cross-reference and variant match before any order is processed.
Q: How do I confirm this stop solenoid fits my Woodward-equipped machine? A: Send the machine model and engine serial number, or a photograph of the existing solenoid showing the nameplate, connector, and mounting flange. The technical team verifies cross-reference 1500-2114 and alternate numbers against your specific governor variant, confirming bolt pattern, pin configuration, and actuator stroke before the order ships.
Q: Are 1502-12A2U1B2 and 1500-2114 interchangeable, or do they cover different variants? A: Both numbers reference the same functional stop solenoid for Woodward 12V systems, but they may map to different production variants with distinct flange patterns or connector types. Physical comparison against your removed unit is necessary to confirm which variant your machine requires. A sample unit can be supplied for trial fitment before bulk commitment.
Q: The old part number on my solenoid is no longer listed β can the alternate number replace it? A: Superseded numbers are common in Woodward fuel system components as production configurations update over time. The cross-reference verification covers discontinued and alternate references, but the replacement must still be checked against your machine's physical interfaces β connector pin-out, flange spacing, and shaft travel β to confirm fitment.
Q: I only have the machine model, no readable part number β can you identify the correct solenoid? A: Yes. A photograph of the machine nameplate, engine data plate, or the solenoid mounting area allows the technical team to narrow down the applicable Woodward governor variant. From there, physical feature matching against known configurations identifies the correct stop solenoid without needing the original part number.
Q: Can I order a sample to test fitment before placing a larger order? A: A single sample unit of stop solenoid 1502-12A2U1B2 can be dispatched for bench fitment testing. This confirms bolt pattern alignment, connector compatibility, and actuator engagement with your specific fuel pump before you commit to a fleet-level quantity, eliminating the risk of a bulk order that does not fit.
Parts available for all major excavator and heavy equipment brands
Guangzhou's trusted excavator parts supplier since 2015
8 core categories for all major brands
Fast dispatch from Guangzhou warehouse
Professional team for part verification
Global shipping with real-time tracking
25-39476-00 Starter Motor, 12V 9T β aftermarket replacement for Carrier CT4-134DI Tier...
View Details
16271-60012 Stop Solenoid Valve, 12V β aftermarket replacement for Kubota D1105, D905...
View Details
H1 655 13721655 ED0021000890S Glow Plug, 12.5V, M12x1.25 thread, 72mm length β...
View Details
Cross-reference numbers verified against our fitment database before dispatch.
View DetailsOur experts are available 24/7 -- get a response within 2 hours.