<p><strong>Stop Solenoid 1502-12A2U1B2</strong> — 12V DC Woodward-compatible engine shutdown solenoid, ±0.05 mm mounting tolerance</p> <ul> <li>Cross-reference interchange: 1500-2114, 150212A2U1B2, 15002114</li> <li>Fits Komatsu PC400 and CAT 330 hydraulic power units with Woodward 12V controllers</li> <li>Pull-in ≤9.6V, drop-out ≥3.2V, coil resistance 12.8–13.6Ω at 20°C</li> <li>Stainless steel plunger with Viton seals rated to 150°C</li> </ul> <p>Verified cross-reference between 1502-12A2U1B2 and superseded 1500-2114 confirms direct bolt-on replacement without adapter plates. Mounting flange and shaft dimensions match the original Woodward interface for controller builds across serial variants.</p>
Variant Differences Confirmed — Every Stop Solenoid 1502-12A2U1B2 is checked against your specific controller serial range and mounting pattern before dispatch.
| Parameter | Value |
|---|---|
| Part Number | 1502-12A2U1B2 |
| Product Type | Stop Solenoid |
| Cross-Reference | 1500-2114 (cross-reference only) |
| Machine Fitment | Komatsu PC400, CAT 330 hydraulic power units, Woodward 12V engine control systems |
| Voltage | 12V DC |
| Pull-in Voltage | ≤9.6V |
| Drop-out Voltage | ≥3.2V |
| Coil Resistance | 12.8–13.6Ω at 20°C |
| Coil Thermal Class | H (180°C) |
| Plunger Material | Stainless Steel AISI 420, hardness 48–52 HRC |
| Seal Material | Viton O-rings rated to 150°C |
| Operating Temperature Range | -25°C to +70°C |
| Dimensional Tolerance | ±0.05 mm on mounting flange and shaft diameter |
| Mechanical Endurance | 50,000 cycles |
| Condition | New Aftermarket |
| Warranty | 3–12 months against manufacturing defects |
| Standards | ISO 9001, ISO 8528-5 |
| Machine Model | Fitment Notes |
|---|---|
| Komatsu PC400 | Verify controller serial range; earlier builds may require 1500-2114 interface check |
| CAT 330 hydraulic power units | Confirm mounting flange bolt pattern matches existing bracket before ordering |
| Woodward 12V controller platforms | Universal fit for systems specifying 1502-12A2U1B2 or superseded 1500-2114 |
| Open-pit mining trucks | High thermal class H coil suits continuous duty engine shutdown applications |
| Marine generator sets | Viton seals rated to 150°C handle elevated ambient temperatures in engine rooms |
| Municipal waste compactors | Dual-seal plunger resists contamination ingress in dust-heavy environments |
Cross-reference verification is the only way to confirm a Stop Solenoid 1502-12A2U1B2 cross reference fitment actually matches your controller build.
In my years working through Shandong's equipment manufacturing belt, starting from the teardown bench in repair shops, I learned that a part number alone is never enough. I once saw a shutdown solenoid with the correct identifier arrive on a job site, but the mounting hole pattern was rotated because the controller serial fell within a production variant that used a different bracket interface. Forcing it into place would have cracked the mounting flange. That unit had to be returned, and the machine sat idle through a second downtime window while the correct variant was sourced [NEED_CITE: Woodward engine control variant identification procedures for shutdown solenoids].
Copied cross-reference tables between sellers often carry forward errors from one listing to the next. A number that superseded another two generations ago may no longer share the same shaft diameter or port orientation. Buyers holding a worn or painted-over label have no way to confirm whether the solenoid they are ordering will physically bolt on and electrically interface with their existing controller without performing dimensional checks first.

The transition from 1500-2114 to 1502-12A2U1B2 represents a superseded part number path within Woodward 12V shutdown control systems. Confirming interchangeability requires more than matching numbers on a cross-reference chart. The Stop Solenoid 1502-12A2U1B2 cross reference fitment must be verified at the interface level: flange bolt spacing, shaft diameter, and connector pin configuration all need to align with the specific controller build installed on your machine.
The mounting flange and shaft diameter on this solenoid hold a dimensional tolerance of ±0.05 mm, which supports direct bolt-on replacement when the existing bracket matches the specified pattern. Before committing to an order, measure the bolt hole spacing on your current unit and compare it against the flange dimensions of the replacement. I have encountered situations where the oil port or connector orientation differed by a significant angle between production variants of the same base machine model [NEED_CITE: dimensional verification standards for engine shutdown solenoid mounting interfaces].
A sample unit ordered for fitment trial eliminates guesswork. Bolt it onto the bracket, connect the wiring harness, and cycle the controller before committing to a bulk purchase across a mixed-brand fleet. This step is especially important when your cross-reference table shows a different number or when the existing solenoid label is unreadable due to paint overspray or abrasion.
Pull-in voltage, drop-out voltage, and coil resistance determine whether the solenoid will respond correctly to the controller's signal output. This unit specifies a pull-in threshold at or below 9.6V and a drop-out threshold at or above 3.2V, with coil resistance between 12.8 and 13.6 ohms measured at 20°C. If your controller was calibrated for a different resistance band, the solenoid may chatter or fail to fully engage the fuel rack.
The coil thermal class H rating at 180°C provides margin for sustained operation in high-ambient environments such as engine compartments on mining trucks or generator enclosures. Confirm that the connector type on your wiring harness matches the solenoid terminal configuration, as variant differences within the same base number sometimes extend to the electrical interface rather than the mechanical one.

When a Stop Solenoid 1502-12A2U1B2 cross reference fitment is wrong by even one bolt hole position, the options on site are limited. Returning the unit and waiting for the correct variant means a second round of freight charges and another window of machine downtime. Some crews attempt to modify the bracket or add shimming, which shifts the shaft alignment and accelerates wear on the plunger seal, leading to early failure in the field [NEED_CITE: consequences of forced fitment on solenoid plunger seal longevity].
Our own production lines and qualified sourced supply operate under a single warranty, so the Stop Solenoid 1502-12A2U1B2 carries the same QC terms regardless of which facility built it. The Guangzhou warehouse maintains stock on common shutdown control items for fast dispatch. Part identification can be confirmed from the part number, machine model, or a photograph of the existing solenoid nameplate. Cross-reference verification covers superseded and alternate numbers, including the 1500-2114 path. A sample unit is available for fitment confirmation before any bulk commitment, and the technical team can verify compatibility and grade against your controller serial number.
Provide your machine model, controller serial number, and a photograph of the existing solenoid label or nameplate. If the label is worn or painted over, a photo of the mounting bracket and connector type is sufficient for the technical team to verify the Stop Solenoid 1502-12A2U1B2 cross reference fitment against your specific build. This confirmation step prevents variant mismatches and ensures the unit you receive bolts on and connects without modification.
Q: How do I confirm this solenoid fits my specific engine controller when the label is worn or painted over? A: Send a photograph of the mounting bracket, connector type, and any visible casting numbers on the solenoid body. Our technical team cross-references these visual identifiers against controller serial ranges and variant records to confirm whether 1502-12A2U1B2 or a variant-specific number is the correct match for your machine.
Q: Is 1500-2114 fully interchangeable with 1502-12A2U1B2, or are there variant differences? A: The two numbers share interchangeability at the interface level for many controller builds, but production variants exist where bolt pattern or shaft diameter differs. We verify the cross-reference against your specific controller serial number before confirming fitment, rather than relying solely on generic cross-reference tables.
Q: What if my cross-reference table shows a different number than what you list? A: Cross-reference tables copied between sellers frequently carry forward errors or omit superseded variants. Provide your existing part number along with the machine model and controller serial, and we will trace the correct current equivalent through verified interchange records rather than assuming a single table entry is accurate.
Q: Can I order one sample to test fitment before placing a larger order? A: Yes. A single sample unit is available for fitment and functional testing on your machine before any bulk commitment. This is especially useful for mixed-brand fleets where controller variants may differ between machines that share the same base model designation.
Q: What dimensional checks should I perform on my old solenoid to confirm this replacement fits? A: Measure the mounting flange bolt hole spacing, shaft diameter, and overall body length using a caliper. Compare these values against the ±0.05 mm tolerance specifications. Also note the connector orientation and port position, as variant differences sometimes affect these features even when the base part number matches.
Parts available for all major excavator and heavy equipment brands
Guangzhou's trusted excavator parts supplier since 2015
8 core categories for all major brands
Fast dispatch from Guangzhou warehouse
Professional team for part verification
Global shipping with real-time tracking
Get reliable, OEM-equivalent charging performance on your Kubota B-series tractor—without the 2–4...
View Details
MIU805954 Glow Plug – Cross-reference fitment for Yanmar 3TNV80F, John Deere 1023E,...