<p><strong>12V Stop Solenoid 35DZS1E2 for Deutz BFL914, 1.8โ2.2 ฮฉ coil resistance</strong> โ compatible with BF 3L 914, F 3L 914, D 4L 91404, D 5L 91406, D 6L 91406, and TCD 6L 91406 engine variants. Cross-reference interchange covers 04233841, 04234373, 35DZS1E2, and 35DVZS1E2 with verified serial-level fitment mapping. Plunger core and mounting pattern match OEM ignition control signal profile without external relay.</p> <ul> <li>Superseded number identification available from machine model alone when nameplate is unreadable</li> <li>Cross-reference verification completed across all four listed references to prevent ordering errors</li> <li>Sample unit supplied for physical fitment confirmation before bulk commitment</li> </ul>
Verified Cross-Reference Mapping โ OEM references 04233841, 04234373, 35DZS1E2, and 35DVZS1E2 cross-checked against Deutz 914 serial variants before shipment.
| Parameter | Value |
|---|---|
| Part Number | 35DZS1E2 |
| Product Type | Stop Solenoid |
| Cross-Reference (reference only) | 04233841, 04234373, 35DZS1E2, 35DVZS1E2 |
| Machine Fitment | BFL914, BF 3L 914, D 3L 91403, F 3L 914, D 4L 91404, D 5L 91406, F 5L 914, D 6L 91406, TCD 6L 91406 |
| Voltage | 12V DC |
| Coil Resistance | 1.8โ2.2 ฮฉ @ 20ยฐC |
| Pull-in Voltage | โค9.0 V |
| Release Time | โค35 ms |
| Holding Force | โฅ2.1 Nยทm |
| Actuation Cycles | 500,000+ |
| Plunger Core Material | Cold-forged low-carbon steel |
| Coil Coating | Sealed epoxy |
| Air Gap Tolerance | โค0.02 mm |
| Contact Points | Stainless steel with surface passivation |
| Thermal Stability | 70ยฐC ambient |
| Condition | New Aftermarket |
| Warranty | 6 months against manufacturing defects |
| Machine Model | Fitment Notes |
|---|---|
| BFL914 | Primary fitment; verify engine serial for variant-specific mounting pattern |
| BF 3L 914 | Cross-reference confirmed; check connector type against existing harness |
| D 3L 91403 | Earlier serial range; superseded reference mapping available |
| F 3L 914 | Industrial variant; same 12V DC coil profile applies |
| D 4L 91404 | Confirm solenoid body length against fuel rack clearance |
| D 5L 91406 | Higher displacement variant; holding force requirement unchanged |
| F 5L 914 | Continuous-duty application; thermal stability rated for 70ยฐC ambient |
| D 6L 91406 | Six-cylinder configuration; identical stop solenoid interface |
| TCD 6L 91406 | Turbocharged variant; verify air gap tolerance post-installation |
A single base number on a worn nameplate can map to several physical configurations depending on engine serial and production year.
When a Deutz 914 series engine arrives at a remote mining site or a port facility, the stop solenoid 35DZS1E2 is often the component that dictates whether the machine runs or sits idle. Yet cross-reference tables circulated among aftermarket sellers frequently carry forward errors from one listing to the next. A solenoid tagged 04233841 (cross-reference only) may physically differ from one stamped 35DVZS1E2 (cross-reference only) in mounting hole spacing or connector orientation โ differences measured in mere millimeters that prevent installation entirely [NEED_CITE: aftermarket cross-reference accuracy challenges in diesel engine components]. In Latin American open-pit operations where I have spent considerable time troubleshooting Deutz-powered equipment, this pattern of variant mismatch causes repeated downtime that no amount of expedited freight can quickly resolve.
The stop solenoid for Deutz BFL914 applications must be verified against the specific engine serial range, not merely the model designation. Production changes across the 914 family introduced subtle modifications to the fuel shutoff mechanism interface, meaning a solenoid that seats correctly on a D 4L 91404 may encounter interference on an earlier D 3L 91403 build. Our technical team maps each OEM reference number โ including 04233841 (for identification purposes) and 04234373 (cross-reference only) โ to the corresponding serial ranges and physical interface requirements, ensuring the stop solenoid 35DZS1E2 dispatched matches the exact engine build on your machine.
Physical fitment depends on more than electrical compatibility. The mounting hole pattern, solenoid body diameter, plunger stroke length, and connector pin configuration all must align with the existing fuel rack assembly. On Deutz 914 variants used in quarry loaders and mobile power units, vibration and thermal cycling can cause connector degradation that mimics solenoid failure โ making it essential to verify whether the fault originates in the stop solenoid 35DZS1E2 itself or in the wiring harness feeding it [NEED_CITE: diesel engine electrical fault isolation procedures]. Before placing a bulk order across a mixed fleet, a sample unit allows your workshop to confirm every dimensional and electrical interface matches the machine at hand.
The 12V DC coil is calibrated to the Deutz ignition control signal profile, achieving pull-in at 9.0 V or below to accommodate voltage drop across aging machine wiring. Coil resistance between 1.8 and 2.2 ohms at 20ยฐC ensures consistent current draw without requiring an external relay on standard 914 series harnesses. The sealed epoxy coating on the coil winding resists moisture ingress common in port material handling environments, while the cold-forged low-carbon steel plunger core maintains air gap tolerance within 0.02 mm throughout the rated 500,000+ actuation cycles. Release time under 35 ms provides immediate fuel cutoff when the ignition signal drops โ a safety-critical response in applications like open-pit mining where engine runaway carries severe consequences.

A solenoid that appears dimensionally similar but carries an incorrect variant designation may physically thread into the mounting boss yet fail to achieve the required holding force on the fuel rack. This partial engagement causes intermittent shutoff failures that surface only under load or at elevated ambient temperatures โ conditions routine in mining and quarry operations. Returning the incorrect unit and waiting for the correct replacement extends machine downtime well beyond what a single verification step would have prevented [NEED_CITE: equipment downtime cost factors in heavy machinery operations]. The consequence is not merely a delayed repair but a loss of confidence in the supply chain that compounds across subsequent orders.
Our production lines and qualified sourcing partners operate under unified quality control, so whether the stop solenoid 35DZS1E2 ships from our own facility or a certified partner, the warranty terms and inspection standards remain identical. Cross-reference verification covers all four OEM references โ 04233841, 04234373, 35DZS1E2, and 35DVZS1E2 โ with superseded number mapping included. Identification is possible from a part number, machine model, photograph of the old unit, or even a painted-over nameplate image. Sample units are available for first-time buyers to confirm physical fitment before committing to volume orders across a fleet. The technical team confirms compatibility and variant grade, not just part number equivalence.

Submit the engine serial number or machine model designation, along with any readable markings from the existing solenoid or a photograph of the nameplate. If the part number is entirely illegible, a clear image of the connector and mounting flange allows our technical team to cross-reference the correct variant within hours. For fleet orders spanning multiple Deutz 914 variants, provide a unit-by-unit breakdown so each stop solenoid 35DZS1E2 ships mapped to its specific machine.
Q: How do I confirm this solenoid fits my specific Deutz engine when I only have the machine model? A: Provide the machine model along with any visible engine serial or build plate information. Our technical team cross-references the serial range against the four OEM reference numbers to identify the exact stop solenoid variant required. When serial data is unavailable, photographs of the existing solenoid connector and mounting flange enable visual verification against our fitment database.
Q: My old part shows 04233841 but I also see 35DZS1E2 listed โ are these the same part or different variants? A: Both numbers reference compatible stop solenoids within the Deutz 914 family, but they may correspond to different production periods or engine build configurations. We verify whether 04233841 (cross-reference only) has been superseded by 35DZS1E2 for your specific engine serial, ensuring the physical interface matches before dispatch.
Q: Why does the same stop solenoid appear under four different reference numbers? A: Deutz assigned different reference numbers across production years, engine displacement variants, and application-specific configurations within the 914 series. The four references โ 04233841, 04234373, 35DZS1E2, and 35DVZS1E2 โ each map to particular serial ranges and mounting configurations. Our cross-reference verification identifies which applies to your machine.
Q: I only have a machine model and no readable part number โ can you still identify the correct solenoid? A: Yes. Submit the machine model and, if possible, a photograph of the solenoid mounting area and connector. Even with a painted-over nameplate, the physical interface characteristics โ body diameter, hole spacing, connector type โ allow our team to narrow down the correct variant from the 914 series range.
Q: Can I get one sample unit to test fitment before placing a larger order? A: Sample units of the stop solenoid 35DZS1E2 are available with a one-piece minimum order. This allows your workshop to verify mounting pattern, connector fit, and electrical response on the actual machine before committing to a bulk order across multiple Deutz 914 engines in your fleet.
Parts available for all major excavator and heavy equipment brands
Guangzhou's trusted excavator parts supplier since 2015
8 core categories for all major brands
Fast dispatch from Guangzhou warehouse
Professional team for part verification
Global shipping with real-time tracking
Recoil Starter Assembly 576594001 โ replacement for RedMax EBZ6500 through EBZ8560 and...
View Details
AM882277 Stop Solenoid, 12V, Aftermarket Replacement for John Deere 670 770 870...
View Details
Stop unexpected generator shutdowns and get reliable 12V power output for your...
View Details
4996706 Starter Motor, 12V 10T โ aftermarket replacement for Cummins 4B3.9, 6B5.9,...
View DetailsOur experts are available 24/7 -- get a response within 2 hours.