12V Stop Solenoid 35DZS1E2 for Deutz 912 913 914 â Verified Fitment
35DZS1E2 Stop Solenoid, 12V, Integrated Diode Protection â replacement for Deutz 912,...
View Details
<p><strong>41-9100, 42-0100, 41-4306, 41-7886, 42-1700 Fuel Stop Solenoid 12V DC, Viton O-rings</strong> â compatible with Thermo King TK249 through TK486V, SLXi, T-Series, and PRECEDENT refrigeration units. Superseded cross-reference numbers verified across generations to confirm connector pin-out, plunger stroke, and mounting flange match your specific model variant. Identification supported from unit model when the nameplate is worn or painted over.</p> <ul> <li>Cross-reference chain mapped: 41-9100 â 42-0100 â 41-4306 â 41-7886 â 42-1700</li> <li>Dimensional tolerance Âą0.05 mm against OEM housing interfaces</li> <li>Sample unit available for bench fitment validation before bulk commitment</li> </ul>
Verified Cross-Reference â supersession path 41-9100 through 42-1700 confirmed for Thermo King transport refrigeration units before dispatch.
| Parameter | Value |
|---|---|
| Part Number | 41-9100, 42-0100, 41-4306, 41-7886, 42-1700 |
| Product Type | Stop Solenoid |
| Cross-Reference | 41-9100, 42-0100, 41-4306, 41-7886, 42-1700 (reference only) |
| Machine Fitment | TK249, TK374, TK388, TK395, TK482, TK482E, TK486, TK486E, TK486V, SLXi Spectrum, SLXi-100/200/300 Whisper Pro/400, SLXe 200â400 & Spectrum-50, SB I/II/III & SB-III Multi-Temp, T-Series (T-580R, T-600R, T-680S, T-800R, T-880R, T-1000S/R, T-1080R/S, T-1200R Spectrum, T-1280 Spectrum), TS-XDS/200/300/500/600, SLX 100â400 & Whisper, SMX, Super II, TriPac APU, KD II, MD 100/200/300/II, RD II/SR, TD II, UTS, SENTRY II, PRECEDENT C-600/G-700/610DE/600M, SL 100â400e & Multi-Temp, SL-400E SR2 |
| Electrical Specification | 12V DC, normally closed (NC), solenoid-actuated fuel shutoff |
| Insulation Class | Class H rated to 180°C |
| Actuation Timing | 0.5ms |
| Cycle Endurance | 500,000+ cycles |
| Sealing Material | Viton O-rings |
| Dimensional Tolerance | Âą0.05 mm |
| Condition | New Aftermarket |
| Warranty | 6-month standard warranty against manufacturing defects |
| Standards | ISO 9001, ISO 16750-4, SAE J1455 |
| Machine Model | Fitment Notes |
|---|---|
| TK486 / TK486E / TK486V | Verify exact variant suffix; connector pin-out and plunger stroke differ across E and V sub-models |
| TK249 through TK395 | Earlier generation units; confirm mounting flange pattern matches original housing interface |
| SLXi Spectrum / SLXi-100â400 Whisper Pro | Cross-reference 42-0100 and 42-1700 apply; verify serial range against supersession table |
| T-Series (T-580R through T-1280 Spectrum) | Multiple reference numbers valid depending on production year; submit current part number for chain verification |
| PRECEDENT C-600 / G-700 / 610DE / 600M | Confirm interface type and port position before ordering; variant-specific fitment required |
| TriPac APU | Auxiliary power unit application; ensure NC configuration matches engine shutdown logic |
Cross-referencing a worn or superseded number without checking variant-level details risks ordering a 12V Fuel Stop Solenoid Valve for Thermo King TK486 that physically fits but fails to actuate.
I have opened service cases where a fleet manager ordered by the stamped number alone, only to find the replacement solenoid had a different connector pin-out or plunger stroke length. Thermo King has revised the stop solenoid design across TK, SLXi, T-Series, and PRECEDENT product lines over multiple production runs. Each revision may change the mounting flange pattern, electrical connector type, or internal stroke dimension while retaining the same base reference. [NEED_CITE: Thermo King service bulletin supersession documentation for fuel shutoff solenoids]
This creates a situation where 41-9100, 42-0100, 41-4306, 41-7886, and 42-1700 all appear in cross-reference tables as interchangeable, yet only one specific variant drops into your unit without modification. Ordering by number alone works until it doesn't â and the failure shows up as a no-start condition on the dock at 5 a.m.

This 12V Fuel Stop Solenoid Valve for Thermo King TK486 carries verified fitment data spanning early TK249 units through current PRECEDENT and T-Series models. The application table above maps each model family to the specific variant checks required before confirming interchangeability. Serial number ranges matter because Thermo King introduced connector and flange revisions at specific production breakpoints, not at model-year boundaries. Submitting your unit model plus serial number lets us pull the exact build specification rather than relying on generalized compatibility charts.
The connector type on this stop solenoid varies between two-pin and three-pin configurations depending on the engine control module generation. Port position and mounting flange bolt pattern must match the existing housing interface within Âą0.05 mm tolerance. We recommend pulling the existing solenoid, photographing the connector face and mounting flange, and sending those images alongside your machine model. This step takes a few minutes and eliminates the cost of return freight on a mismatched batch. [NEED_CITE: aftermarket component interface verification standards for transport refrigeration] Requesting a single sample unit for bench fitment before committing to fleet quantities is standard practice here.
Class H insulation rated to 180°C keeps the solenoid coil functional in the engine compartment environment where ambient and radiant heat combine. Standard Class B or Class F insulation would degrade under sustained transport refrigeration duty, leading to intermittent actuation failures that are difficult to diagnose on the road. The 0.5ms actuation timing ensures the fuel shutoff responds within the engine control module's expected window, preventing delayed shutdown sequences that can cause backfire or after-run in diesel engines. Viton O-rings maintain seal integrity against diesel fuel across the full operating temperature range, whereas NBR seals swell and lose durometer after prolonged fuel contact. The 500,000+ cycle endurance rating translates to multi-year service in typical cold chain logistics operations where the unit cycles multiple times daily.

A stop solenoid with the wrong stroke length may seat partially, allowing fuel weepage that prevents clean engine shutdown. This shows up as extended cranking on the next start or, worse, engine run-on after the key is turned off. A connector with mismatched pin-out can blow the control circuit fuse, taking the entire refrigeration unit offline until the wiring fault is traced. These are not catastrophic failures â they are the kind of nuisance faults that consume technician hours and erode confidence in the repair. [NEED_CITE: transport refrigeration unit electrical fault diagnostic procedures] The downtime cost is rarely the part itself; it is the loaded trailer sitting on the dock while the electrician diagnoses a problem that should not have existed.
Each unit ships with a cross-reference verification sheet documenting which numbers in the 41-9100 through 42-1700 supersession chain apply to your specific machine model. Our technical team confirms connector type, flange pattern, and stroke length against your submitted unit data before release. Both self-produced and sourced supply lines carry identical QC protocols and the same six-month warranty. Guangzhou warehouse stock enables rapid release on common configurations. We support part identification from a worn nameplate photograph, a machine model alone, or an existing part number â whichever is the only data you have available. Sample units ship for bench fitment confirmation before any bulk commitment is required.
Send us your Thermo King unit model, serial number, or a photograph of the existing solenoid nameplate and connector face. We will return a verified cross-reference path and confirm which variant in the supersession chain fits your specific build. If you are standardizing across a mixed fleet, provide the full model list and we will map each unit to the correct configuration before quoting.
Q: How do I confirm this solenoid fits my specific Thermo King unit model and serial range? A: Submit your unit model designation and serial number, or a clear photograph of the existing solenoid showing the connector and nameplate. We cross-reference against the verified supersession path covering 41-9100, 42-0100, 41-4306, 41-7886, and 42-1700 to confirm the exact variant that fits your build, including connector type and flange pattern.
Q: Are 41-9100 and 42-0100 interchangeable, or do they cover different model variants? A: Both numbers appear in the supersession chain but may apply to different production runs or model sub-variants. Interchangeability depends on your specific unit serial range and engine control generation. Submit your current part number and machine model so we can confirm which reference applies rather than assuming blanket interchangeability.
Q: My nameplate is worn off â can you identify the right part from just the machine model? A: Yes. Provide the Thermo King unit model designation visible on the main chassis plate, along with a photograph of the existing solenoid connector and mounting flange. We use the machine model to narrow the serial range, then verify the physical interface against our fitment database to confirm the correct stop solenoid variant.
Q: Why are there multiple OEM reference numbers for what appears to be the same solenoid? A: Thermo King revised the solenoid design across product generations, updating connector types, flange patterns, and internal stroke dimensions. Each revision received a new reference number. The supersession chain exists because earlier numbers remain valid for older units while newer variants serve current production, making cross-reference verification essential.
Q: Can I get a sample to confirm fitment before ordering for my whole fleet? A: Yes. Single-piece sample orders ship for bench fitment and functional validation. Install the sample on one unit, verify connector engagement, flange alignment, and shutdown function, then confirm bulk quantities. This approach eliminates the risk of receiving a fleet quantity of mismatched components based on an unverified cross-reference.
Parts available for all major excavator and heavy equipment brands
Guangzhou's trusted excavator parts supplier since 2015
8 core categories for all major brands
Fast dispatch from Guangzhou warehouse
Professional team for part verification
Global shipping with real-time tracking
35DZS1E2 Stop Solenoid, 12V, Integrated Diode Protection â replacement for Deutz 912,...
View Details
Get your Kohler-powered equipment back online fast â no more downtime waiting...
View Details
1G820-60022 Stop Solenoid Valve, 12V, replacement for Kubota D722, D782 and D902...
View Details
365-3339 Stop Solenoid, 12V, fits CAT 3013C, 3024C, C2.2 engines and loader/compactor...
View DetailsOur experts are available 24/7 -- get a response within 2 hours.