12V 2.2KW Starter Motor 6670727 – Fits Bobcat 325 E35 E50
12V 2.2KW Starter Motor 6670727 — replacement for Bobcat compact excavators and...
View Details
<p>Cross-reference verification completed and sample available for fitment trial before bulk commitment.</p>
Variant-level cross-reference verified — we match 7167-620B and 9009-049 solenoids to specific CAV and Lucas pump serial ranges, eliminating fitment surprises at the workshop bench.
| Parameter | Value |
|---|---|
| Part Number | 7167-620B |
| Product Type | Stop Solenoid |
| Cross-Reference | 7167-620B (reference only), 7167620B (reference only), 9009-049 (reference only), 9009049 (reference only) |
| Machine Fitment | Lucas C-Series, D-Series, E-Series diesel injection pumps; CAV DPA, DPS, DBA, DBS fuel injection pumps; standard DPA and DPS rotary distributor pump applications |
| Voltage | 12V DC |
| Operating Temperature | -20°C to +85°C |
| Peak Inrush Current | 4.2A |
| Response Time | ≤15ms |
| Pressure Rating | 12 bar static |
| Sealing | Dual nitrile rubber O-rings |
| Terminal Pin Material | Tinned copper, 2.5mm² cross-section |
| Armature Core Material | Cold-forged low-carbon steel |
| Dimensional Tolerance | ±0.08 mm on mounting and sealing surfaces |
| Condition | New Aftermarket |
| Warranty | 6 months against manufacturing defects |
| MOQ | 1 piece |
| Standards | ISO 9001, ISO 8528-5 |
| Machine Model | Fitment Notes |
|---|---|
| CAV DPA rotary distributor pumps | Verify pump series letter and serial range; connector type varies across production runs |
| CAV DPS rotary distributor pumps | Confirm mounting flange orientation and terminal pin layout before ordering |
| CAV DBA / DBS fuel injection pumps | Cross-check solenoid body length against existing unit; some variants carry a shorter stroke |
| Lucas C-Series diesel injection pumps | Early-production units may carry superseded reference numbers no longer listed in current catalogs |
| Lucas D-Series diesel injection pumps | Most common application for 7167-620B interchange reference; dual O-ring seal matches factory groove |
| Lucas E-Series diesel injection pumps | Later-production variant; confirm plug receptacle shape as some units migrated to a molded connector |
| Excavator engines using DPA/DPS pumps | Machine model alone is insufficient; pump serial number needed for variant-level confirmation |
| Generator set diesel power units | Stationary duty may see higher thermal soak; verify ambient temperature stays within rated range |
The 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference covers multiple pump generations, and a copied table rarely tells you which variant your pump actually needs.
On Indonesian job sites I have watched excavators sit idle because a 12V stop solenoid arrived with the correct base number but the wrong connector plug — the pump had been swapped during a prior rebuild and the serial range no longer matched the original equipment list. [NEED_CITE: diesel injection pump serial range identification practices] Superseded numbers compound the problem: an older reference may point to a solenoid body that is dimensionally correct but carries a different terminal pin configuration, leaving the wiring harness unable to mate. This 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference addresses that gap by tying each interchange number to specific pump series and serial boundaries rather than treating them as universal equivalents.
CAV DPA and DPS pumps have been produced across several decades, and running changes to the stop solenoid cavity depth, O-ring groove position, and electrical connector format mean that two solenoids sharing a base designation can behave differently under pressure. We map each variant of the 7167-620B interchange reference against the pump series letter and serial number prefix so that the armature stroke, sealing surface, and terminal pin layout all align with your specific pump build. When only a machine model is available, we request the pump data plate or a photograph of the existing solenoid to confirm which variant applies before any commitment is made.

The physical interface is where most identification errors surface after delivery. The dual nitrile O-ring seal must sit squarely in the pump body groove without binding or floating, and the ±0.08 mm tolerance on the mounting surface ensures the solenoid seats flush against the DPA or DPS housing. Terminal pin material and cross-section determine whether the existing wiring harness plug will accept the new unit — tinned copper at 2.5mm² matches the standard CAV and Lucas harness receptacle, but later E-Series pumps occasionally use a molded connector with a different keyway. [NEED_CITE: diesel fuel system electrical connector identification standards] We check port position, pin count, and connector type against your existing installation photograph before confirming fitment.
A 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference must handle the initial inrush current spike without overheating during sustained engine operation. The 4.2A peak inrush rating reflects the current draw during the first milliseconds when the armature moves from rest to the open position, after which holding current drops substantially. The cold-forged low-carbon steel armature core maintains magnetic permeability across the -20°C to +85°C operating window, preventing sluggish response in cold starts or thermal saturation during tropical afternoon shifts. The ≤15ms response time ensures the fuel rack cuts cleanly when the ignition is switched off, avoiding the run-on and dieseling that signal a slow-closing solenoid. Operating outside the rated temperature band accelerates O-ring hardening, which then allows fuel weepage past the sealing surfaces.

A solenoid that physically threads into the pump cavity but carries the wrong stroke length can leave the fuel rack partially open, causing erratic idle or failure to shut down. Conversely, a unit with the correct electrical connector but a slightly different body diameter may bind during installation, scoring the pump bore and creating a leak path that worsens over time. [NEED_CITE: diesel injection pump bore scoring consequences on fuel system integrity] The return freight, the second downtime window for removal, and the delayed project schedule all compound a problem that originated from a cross-reference table that did not distinguish between variants. We send a sample unit for bench-fitment confirmation when fleet-level orders are at stake, so the first piece proves the match before the balance ships.
Every inquiry we handle starts with what you can see on the pump or in the cab. If the existing solenoid label is worn or painted over, a photograph of the connector face and the pump data plate lets our technical team narrow down the correct variant from the Lucas C, D, or E-Series range. We cross-reference superseded and alternate numbers — including 9009-049 and 9009049 interchange references — to trace which original number your pump left the factory with and which current production solenoid replaces it. The 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference we confirm is the one that matches your specific pump serial range, connector format, and sealing interface, not merely the one that shares a base number in a generic table.
Q: How do I confirm this solenoid fits my specific pump model and serial range? A: Send us the pump data plate photograph showing the series letter and serial number prefix. We cross-reference your number against the CAV and Lucas serial range records and confirm which variant of the 7167-620B interchange reference matches your connector type and sealing interface. Machine model alone is not enough for a definitive match.
Q: My existing part number is worn or painted over — can you identify it from the pump model? A: Yes. A clear photograph of the solenoid body, the connector face, and the pump data plate lets us narrow down the correct variant. We compare mounting dimensions, pin count, and O-ring groove position against known CAV and Lucas configurations to identify the right 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference even when the label is unreadable.
Q: Why are there multiple part numbers listed for what looks like the same solenoid? A: CAV and Lucas updated solenoid designs across production runs, changing connector formats and body dimensions while retaining similar base numbers. The 9009-049 interchange reference and 7167-620B interchange reference may both appear valid but apply to different pump serial ranges. We determine which one fits your specific unit before shipping.
Q: Can I get a sample to verify fitment before ordering for my whole fleet? A: A single-piece sample is available so you can bench-fit it against one pump and confirm the connector, seal, and armature stroke match. Once fitment is verified, we ship the balance of the fleet order with the same variant specification. Our minimum order is one piece, so there is no volume threshold to clear first.
Q: What if the cross-reference I found online doesn't match your recommendation? A: Online tables frequently carry forward errors from outdated catalogs or merge variants that CAV and Lucas kept separate. We verify each 12V Fuel Cut-off Solenoid for DPA DPS CAV Lucas cross reference against pump serial range, connector format, and dimensional records rather than relying on a single source. Share the conflicting reference and your pump details so we can explain the discrepancy.
Parts available for all major excavator and heavy equipment brands
Guangzhou's trusted excavator parts supplier since 2015
8 core categories for all major brands
Fast dispatch from Guangzhou warehouse
Professional team for part verification
Global shipping with real-time tracking
12V 2.2KW Starter Motor 6670727 — replacement for Bobcat compact excavators and...
View Details
Get your Yanmar 3TNV82/3TNV88 engine or Northern Lights NL484 generator cranking reliably—every...
View Details
06129901/06129902 Cushion Damper, Shore A 65±3, High-Elasticity Natural Rubber — replacement rubber...
View Details
Fitment cross-reference independently verified before dispatch.